7) Click on the “uvicalib” tab. Column A calculates the colour temperature adjustment
required to compensate for the difference in colour temperature between D65 (the
colour temperature at which the colour calibration is carried out for the VIS images - see
workflow for the correction of VIS images) and the colour temperature at which the
VIS images are acquired. This is described in more detail in Chapter 1.

8) Move the slider at Al (Figure 3-65) to select the VIS illuminant colour temperature, from
a source with known colour temperature (e.g. for a D50 flash, choose the 5000K) or as
measured with a colour temperature meter. A9 shows the resultant white-point

T 65346. antonine lady.ws (F:\Technical Imaging\WP10.3b_c meeting\Materials\Test Images) - uvicalib - nip2

Eile Edit View Toolkits Help

[input linear marta [iscatb [vet Jaen specden falsecolour uvistray uvkm_ vilstray vilkm | results +
Y A- visible illuminant colour temperature x \ve- apply camera calibration and white-point adjustment x

>| At |macbeth illuminant colour temperature: {5000 | === | >| B1 | viscalib.D8

label | UV-induced visible luminescence

targets_label | UV-induced visible luminescence with calibration targets, colour-calibrated

object label | UV-induced visible luminescence of object, colour-calibrated

J) to convert to: | xvz >]

Colour_convert_item.X¥Z_item.action A2

A
S object

| A4 | target colour temperature — nip2 neutral is DES

AS viscalib.Apply. calib B1 B2

>| 86 label | UV-induced visible luminescence

A

> targets

>

<>

| space [colour space: | Lab
a)
v

a

Colour_new_item.Widget_colour_item.action S) object

‘a6 |
Apply_ct A9 B3

iA a
S| to |Convert to: | xvz s]

Colour. convert, item. XYZ. item. action AS

colour | Colour value: (50, 0, 0]

<>

[a7 2.71464

| 48 | calculated white-point adjustment to get to D65

wo | c
CR ID]
A stant] 628 (D)inbox...| (w] cheap... | Gp Pecs | > Test 1... | HB unsav...|[H 6534. (P)Fig3_...| (W] chapt...[ { Seaich Deskior O80 8 GB 11:47

Figure 3-65

9) Scroll right to column B, which applies the colour calibration for the VIS image
(automatically carried over to B1 from the “viscalib” tab) to the UVL images to be
calibrated (automatically carried over to B2 from the “linear” tab).

10) The colour calibrated images can be seen at B3 (Figure 3-65). Note that the calibration
is applied to the images at both the “target” and “object” thumbnails, which can be the
same image (as in Figure 3-65) or another image taken with the same camera and
under the same lighting conditions (Figure 3-66).

11) The adjustment is applied to the images at B3 to give the colour-calibrated and white
point adjusted images at B6 (Figure 3-65 and Figure 3-66).

12) Figure 3-67 shows a comparison of one of the image sets discussed above before
(right) and after calibration (left).

Version No. 1.0 156 Date : 14/10/2013