OCR Output

cn A B 7

Workflow for the correction of IR and/or UV-reflected images (IRR/UVR) and the
generation of IR and/or UV-reflected false-colour (IRRFC/UVRFC) images.

Check that the all images or other information required in order to run this workspace is
available:

e Calibrated VIS image(s) (including a Spectralon diffuse reflectance grey scale or any
number of Spectralon diffuse reflectance standards as available) obtained by
processing the corresponding visible-reflected image(s) using the workflow for
correction of visible-reflected images (See above);

e Camera output file (TIFF) — IR and/or UV-reflected images (including a Spectralon
diffuse reflectance grey scale or any number of Spectralon diffuse reflectance
standards as available) converted from RAW as per instruction in section a;

e ICC profile for conversion from RAW (contained within the TIFF file);

e Image(s) of uniform reflective board under experimental conditions of IR and/or UV¬
reflected images for flat fielding, if available.

Loading the input images

1) Note that the previous workflow for correction of visible-reflected (VIS) images must
already have been completed prior to running through this workflow. If this has not been
done, return to section i and proceed as directed before continuing.

2) Click on the “input” tab (Figure 3-39), the second row of columns on the left (column E
and F) hold the input images required for this workflow (correction of IR and/or UV¬
reflected images). If these were not uploaded previously, add them as directed below.

Eile Edit View Tookits Help
[rest ras markup viscalib uvicalib align specden falsecolour uvistray uvikm vilstray vikm results +

light reflectance % | v E- IRreflectance X Ive
“i al A

del | visible reflectance E2 label | IR reflectance G2

v Vv
A

ots label | visible reflectance with calibration targets a] targets label | IR reflectance with calibration targets

image | is image
j

use_flatfield | (] Flatfield visible reflectance with calibration targets image |S | use_fatfield | &) Flatfield IR reflectance with calibration targets image

8 Vé
iS iS

i i
—_ _ EE i

Pair_flatfield NULL (label ++ " with calibration targets") | Pair_flatfield NULL (label ++ " with calibration targets")

<>

lA

label | visible reflectance of object object label ! IR reflectance of object
—_= dic v

lA
d ie image
i

use, 7 0 Flatfield visible reflectance of object image use_flatfield | 67] |Flatfield IR reflectance of object image

<>

A A
v ív
A A
lv] fiatfeld S| fiatfield

TI Tt
®

tput images as 16-bits? x Vw F- UVreflectance x
cal input image S| re label | UV reflectance

0 targets label | UV reflectance with calibration targets
bo a
1 a ee B
@start| € 2 @ 0} D)inbox-...| a worksp... | (Wi) chopter...| iB unsave... |[E*FATec... (P) VIS wor... | (P)IRRUVR... [BHO B & 1231

Figure 3-39

3) Images are opened by dragging them into the appropriate slot or by left-clicking on the
thumbnail, clicking “Replace From File”, and selecting the image required (Figure 3-40).

Version No. 1.0 137 Date : 14/10/2013