Skip to main content
mobile

Heritázs

  • Pretraga
  • Kolekcije
Serbo-Croatiansh
  • Englishen
  • Magyarhu
  • Српскиsr
PrijavaRegistruj
  • Pregled Naslova
  • Stranica
  • Tekst
  • Metapodaci
  • Isečak
Pregled
srb_000007/0000

Charisma - J_Dyer_G_Verri_and_J_Cupitt_Multispectral

  • Pregled
  • Prikaži metapodatke
  • Prikaži Permalink
Ukupno stranica
192
Kolekcija
Presentations of MSI conference in Serbia
srb_000007/0166
  • Pregled Naslova
  • Stranica
  • Tekst
  • Metapodaci
  • Isečak
Stranica 167 [167]
  • Pregled
  • Prikaži Permalink
  • JPG
  • TIFF
  • Preth.
  • Sledeće
srb_000007/0166

OCR

cas A NI 7 19) The points are moved by left-clicking and dragging on the label. Move these to indicate a pair of features on the standards which are recognisable in both images. Better accuracy is achieved if these points as far apart as possible. Note that it is not essential to use the standards themselves for the alignment (which may be difficult if, for example, the image is quite dark), as long as these are correctly aligned in both images. Note that the image will update in real time, which may cause a slight response delay in larger images. {3 *F:\ Technical Imaging\ John Cupitt\zip files\bm2\bm-workspaces2.ws - align = =/5)> File Edit View Tookits Help peg input | linear | markup " viscalb . uvicalb | align | specden . falsecolour | KELETT Elle View Help Vo A- match UV-induced visible luminescence to vis x i 2592x3888 32-bit float, 3 bands, XYZ, 115.33 MB, 1x1 pimm (2591, 1050) _0.907281_0.260463_0.620769__ Magnification 1:6 A S| a1 | uvicalib.26 <> Ce ee eA RES adjust A v < D) 1 Figure 3-69 20) To test the accuracy of the alignment, double left-click on the A2 “test_alignment” thumbnail (Figure 3-70). 21) Scroll down to the VIS and UVL images to be calibrated (A3). These can be the same as those in A2 (as shown in the above examples) or different images (as in Figure 3-71). 22) Double left-click on the A3 “reference” thumbnail to bring up the image view window containing the VIS image and two points, A3.apl and A3.ap2. These should be automatically placed in the same locations as for the D1 “reference” VIS image. Zoom in or out of the image as necessary by pressing “+” or “-” (or “i” or “o”) respectively. 23) Move these to indicate a pair of features which are recognisable in both images. Better accuracy is achieved if these points as far apart as possible. Note that the image will update in real time, which may cause a Slight response delay in larger images. Version No. 1.0 159 Date : 14/10/2013

Strukturalno

Custom

Image Metadata

Širina slike
2481 px
Visina slike
3508 px
Rezolucija slike
300 px/inch
Veličina originalnog fajla
1.3 MB
Permalink ka JPG-u
srb_000007/0166.jpg
Permalink ka OCR-u
srb_000007/0166.ocr

Privaci

  • Politike privatnosti
  • Kolačići

  • https://facebook.com/tripont

Veb Sajt

  • heritazs.hu
  • phaseone.hu
  • tripont.hu
  • tripont.hu/problog

Kontakt

  • +36 30 462 23 40
  • klinger.gabor@tripont.hu
  • 1131 Budapest,
  • Reitter Ferenc utca 132/J.

  • Copyright © 2023 Tripont Kft.
  • Copyright © 2024 Tripont Kft.

Heritázs

PrijavaRegistruj

User login

Zaboravio sam šifru
  • Pretraga
  • Kolekcije
Serbo-Croatiansh
  • Englishen
  • Magyarhu
  • Српскиsr