Skip to main content
mobile

Heritázs

  • Pretraga
  • Kolekcije
Serbo-Croatiansh
  • Englishen
  • Magyarhu
  • Српскиsr
PrijavaRegistruj
  • Pregled Naslova
  • Stranica
  • Tekst
  • Metapodaci
  • Isečak
Pregled
srb_000007/0000

Charisma - J_Dyer_G_Verri_and_J_Cupitt_Multispectral

  • Pregled
  • Prikaži metapodatke
  • Prikaži Permalink
Ukupno stranica
192
Kolekcija
Presentations of MSI conference in Serbia
srb_000007/0164
  • Pregled Naslova
  • Stranica
  • Tekst
  • Metapodaci
  • Isečak
Stranica 165 [165]
  • Pregled
  • Prikaži Permalink
  • JPG
  • TIFF
  • Preth.
  • Sledeće
srb_000007/0164

OCR

A= visible illuminant colour temperature 3% |v |B- apply camera calibration and white-point adjustment x CIA |macbeth illuminant colour temperature: (5000 S—G— | B1 | viscalb.08 | 22 | linear. 316 Es v 83 | label | UV-induced visible luminescence targets_label | UV-induced visible luminescence with calibration targets, colour-calibrated la ís targets object label ] UV-induced visible luminescence of object, colour-calibrated ) S object 4 Colour_convert_item.XYZ_item.action A2 als | 4 | target colour temperature — nip2 neutral is D65 _ Catt AS viscalib.Apply. calib B1 82 €186] | label) Uv-induced visible luminescence iS space [Colour space: | Lab s] 2) colour | Colour value: (50, 0, 0] Colour_new_item.Widget_colour_item.action 46 <> Apply_ct A9 B3 Sto convert wo: [xyz Ta Colour. convert, item.XYZ. item. action AS 147 | 2.71464 [as calculated white-point adjustment to get to D6S ar d b) Bsmt] BBG) — ioc cat [d wna. [/d6szos [fá seater (B]UM wer. (Ginter. [500770 [a BIO SG ons Figure 3-66 lo) x!) (1239, 57) 2.28478 2.48976 4.50653 Magnification 1:3 Figure 3-67 13) The sRGB (or RGB16) colour calibrated UVL images can be viewed and saved in the “results” tab (See later). Image registration: aligning the calibrated VIS and UVL images. 14) Click on the “align” tab and scroll right. Column A registers the VIS and the UVL images (Figure 3-68). 15) Two sets of images are observed to allow the independent registration of the Spectralon diffuse reflectance standards in the images containing these (A2) and the images themselves (A3). This allows greater flexibility in order to address various scenarios: (a) Where the images used for calibration are the same images to be calibrated and no alteration in the position of the standards has occurred in the VIS vs. the UVL images (as in Figure 3-68). This would be the expected situation in a studio setting; (b) As above but some alteration in the position of the standards has occurred in the VIS vs. UVL images; Version No. 1.0 157 Date : 14/10/2013

Strukturalno

Custom

Image Metadata

Širina slike
2481 px
Visina slike
3508 px
Rezolucija slike
300 px/inch
Veličina originalnog fajla
1.29 MB
Permalink ka JPG-u
srb_000007/0164.jpg
Permalink ka OCR-u
srb_000007/0164.ocr

Privaci

  • Politike privatnosti
  • Kolačići

  • https://facebook.com/tripont

Veb Sajt

  • heritazs.hu
  • phaseone.hu
  • tripont.hu
  • tripont.hu/problog

Kontakt

  • +36 30 462 23 40
  • klinger.gabor@tripont.hu
  • 1131 Budapest,
  • Reitter Ferenc utca 132/J.

  • Copyright © 2023 Tripont Kft.
  • Copyright © 2024 Tripont Kft.

Heritázs

PrijavaRegistruj

User login

Zaboravio sam šifru
  • Pretraga
  • Kolekcije
Serbo-Croatiansh
  • Englishen
  • Magyarhu
  • Српскиsr