Ugrás a tartalomra
mobile

Heritázs

  • Keresés
  • Gyűjtemények
Magyarhu
  • Englishen
  • Српскиsr
  • Serbo-Croatiansh
BejelentkezésRegisztráció
  • Kötet áttekintése
  • Oldal
  • Szöveg
  • Metaadatok
  • Kivágás
Előnézet
srb_000007/0000

Charisma - J_Dyer_G_Verri_and_J_Cupitt_Multispectral

  • Előnézet
  • Metaadatok mutatása
  • Permalink mutatása
Összes oldal
192
Gyűjtemény
Presentations of MSI conference in Serbia
srb_000007/0150
  • Kötet áttekintése
  • Oldal
  • Szöveg
  • Metaadatok
  • Kivágás
Oldal 151 [151]
  • Előnézet
  • Permalink mutatása
  • JPG
  • TIFF
  • Előző
  • Következő
srb_000007/0150

OCR

CHARISM A I 7 15) If the image is too dark or light, click View > Toolbar and check the “Display Control” box. This will bring up a slider which allows the brightness to be adjusted. This change is purely for visual purposes and will not alter the data. 16) To test the accuracy of the alignment, double left-click on the D26 “test_alignment” thumbnail (Figure 3-48). This shows monochrome versions of the VIS and IRR images in the green and red channels, respectively. The IRR image is transparent and overlaid onto the VIS image to enable the accuracy of the alignment to be easily visualized. (\ *F:\Technical Imaging\ John Cupitt\zip files\bm2\\bm-workspaces2.ws - align -l5)> 17 Y D- match IR to vis . §] 01023 "viscalib.H10 92x3888 32-bit float, 3 bands, XYZ, 115.33 MB, 9.45x9.45 pimm — 42) 7.79514 24.6662 0 Magnification 1:6 >| 024 | tinear.ke ——————— a v <>) <1 6 ae S| 01 P | | ah Aistat| € a B 0) [D)inbox...| (Wi) chap... /(BJIRRU.. |W unsav...| Wear... [38 0260... | MH 026.0../[H 0264... | Seach Desktop SPH UO B G 1315 Figure 3-48 17) Scroll down to the VIS and IRR images to be calibrated (D1). These can be the same as those in D26 (as shown in the above examples) or different images (as in Figure 3-49). 18) Double left-click on the D1 “reference” thumbnail to bring up the image view window containing the VIS image and two points, Dl.ap1 and D1.ap2 (Figure 3-49). Zoom in or out of the image as necessary by pressing “+” or “-” (or “i” or “o”) respectively. Note that the image will update in real time, which may cause a slight response delay in larger images. 19) Move these to indicate a pair of features which are recognisable in both images. Better accuracy is achieved if these points as far apart as possible. 20) Repeat the procedure for the IRR image by double leftclicking on the D1 “adjust” thumbnail and moving the points D1.bp1 and D1.bp2 to the same locations as for the VIS image. 21) Test the accuracy of the alignment by double left-clicking on the D1 “test_alignment” thumbnail. Version No. 1.0 143 Date : 14/10/2013

Szerkezeti

Custom

Image Metadata

Kép szélessége
2481 px
Kép magassága
3508 px
Képfelbontás
300 px/inch
Kép eredeti mérete
1.37 MB
Permalinkből jpg
srb_000007/0150.jpg
Permalinkből OCR
srb_000007/0150.ocr

Adatvédelem

  • Adatvédelmi szabályzat
  • Süti – Cookie kezelése

  • https://facebook.com/tripont

Oldalink

  • heritazs.hu
  • phaseone.hu
  • tripont.hu
  • tripont.hu/problog

Kapcsolat

  • +36 30 462 23 40
  • klinger.gabor@tripont.hu
  • 1131 Budapest,
  • Reitter Ferenc utca 132/J.

  • Copyright © 2023 Tripont Kft.
  • Copyright © 2024 Tripont Kft.

Heritázs

BejelentkezésRegisztráció

Bejelentkezés

Elfelejtettem a jelszavamat
  • Keresés
  • Gyűjtemények
Magyarhu
  • Englishen
  • Српскиsr
  • Serbo-Croatiansh