Skip to main content
mobile

Heritázs

  • Pretraga
  • Kolekcije
Српскиsr
  • Englishen
  • Magyarhu
  • Serbo-Croatiansh
PrijavaRegistruj
  • Pregled Naslova
  • Stranica
  • Tekst
  • Metapodaci
  • Isečak
Pregled
srb_000007/0000

Charisma - J_Dyer_G_Verri_and_J_Cupitt_Multispectral

  • Pregled
  • Prikaži metapodatke
  • Prikaži Permalink
Ukupno stranica
192
Kolekcija
Presentations of MSI conference in Serbia
srb_000007/0134
  • Pregled Naslova
  • Stranica
  • Tekst
  • Metapodaci
  • Isečak
Stranica 135 [135]
  • Pregled
  • Prikaži Permalink
  • JPG
  • TIFF
  • Preth.
  • Sledeće
srb_000007/0134

OCR

cn A B 7 9) Move the endpoints of the line A21 (Figure 3-26) so that the line follows any of the edges of the Macbeth chart. The image will be rotated to straighten it. Zoom in or out of the image as necessary by pressing “+” or “-” (or “i” or “o”) respectively. Note that the image will update in real time, which may cause a slight response delay in larger images. File Edit View Tookits Help | input / linear | markup ( viscalb |uvicalb align | specden , falsecolour , uvistray uvkm viltray vikm results Papernem—newemenrers Eile View Help Image, 2629x3912 32-bit float, 3 bands, XYZ, 117.70 MB, 9.45x9.45 p/mm | ( 42, 3911) 10.9622 — 12.1818 — 17.2872 Magnification 1:6 VA - mark position of Macbeth in visible-light reflectance image a 01421) | straighten prompt | Put line along edge of Macbeth v A >) straighten image Ji i] | line Arrow on [B1 .straighten, image, AZ1.straighten. image) at (1992, 558), offset (-6, 636) enclose_prompt | Enclose the Macbeth with box S| angle [Rotate by: [90 degrees anticlockwise rotate_widget 0 box Markup_macbeth linear.313 | z Astat| 6B o (hire... | (W}che...| (P)vis... | Coram _| 3B uns... | Wl A... [dd FA... [dd Azt. [PH Aza [Soci Desktop [089320 SG 1512 Figure 3-27 10) Next, double left-click on the “box-image” thumbnail (Figure 3-27) and adjust the box A21 on the image view window so that it just encloses the chart. The selection appears in the “box” thumbnail. 11) Finally pick a rotation option from the drop-down menu in the “rotate” thumbnail (Figure 3-27) that orients the Macbeth chart correctly, with the white patch in the bottom lefthand corner. 12) Scroll right. Column B marks the position of the Spectralon diffuse reflectance grey scale or any number of Spectralon diffuse reflectance standards as available, from the image in B1. Note that this step is required for later workflows and can be omitted if only correcting visible-reflected images. 13) Double left-click on the “straighten_image” thumbnail to open an image view window (Figure 3-28). 14) Move the endpoints of the line B1 so that the line follows the edge of the Spectralon diffuse reflectance grey scale (Figure 3-28) or the available Spectralon diffuse reflectance standards (as in Figure 3-29). The image will be rotated to straighten it. Zoom in or out of the image as necessary by pressing “+” or (or “i” or “o”) respectively. Note that the image will update in real time. Version No. 1.0 127 Date : 14/10/2013

Strukturalno

Custom

Image Metadata

Širina slike
2481 px
Visina slike
3508 px
Rezolucija slike
300 px/inch
Veličina originalnog fajla
1.35 MB
Permalink ka JPG-u
srb_000007/0134.jpg
Permalink ka OCR-u
srb_000007/0134.ocr

Privaci

  • Politike privatnosti
  • Kolačići

  • https://facebook.com/tripont

Veb Sajt

  • heritazs.hu
  • phaseone.hu
  • tripont.hu
  • tripont.hu/problog

Kontakt

  • +36 30 462 23 40
  • klinger.gabor@tripont.hu
  • 1131 Budapest,
  • Reitter Ferenc utca 132/J.

  • Copyright © 2023 Tripont Kft.
  • Copyright © 2024 Tripont Kft.

Heritázs

PrijavaRegistruj

Пријављивање корисника

Zaboravio sam šifru
  • Pretraga
  • Kolekcije
Српскиsr
  • Englishen
  • Magyarhu
  • Serbo-Croatiansh